  1. Laboratory

    Accumark Labs issued this certificate. Its name and the exact report code are the starting point for an issuer lookup.

  2. Client

    The client is Valor Peptides. The report describes the sample Valor submitted under this name.

  3. Report code and dates

    Report 3ZGM-4DQL; sample received 2026-09-21, certificate published 2026-09-24. Published is the date printed here; it is not labelled an analysis date.

  4. Identity, nominal size and lot

    The nominal sample size is 70.0 mg and the lot is ARC-GL70-009. Match the compound, size and lot when comparing a product with this report.

  5. Measured quantity and purity

    The headline measured quantity is 61.79 mg, and the reported chromatographic purity is 99.84%. Quantity and purity answer different questions.

  6. Laboratory results

    Identity and purity are marked Conforms. Quantity is marked Measured: that label records an amount rather than a laboratory pass/fail judgment against the nominal size.

  7. Chromatogram

    The plotted HPLC signal accompanies the reported purity result. Peak area, chromatographic purity and vial mass are different measurements.

  8. Certification and lookup

    The footer repeats 3ZGM-4DQL beside the issuer QR code and certification date. Use the specific issuer record linked below to compare the complete PDF.

Page 1 of 3. Tap a section to open the complete page.

  1. Laboratory

    Accumark Labs issued this certificate. Its name and the exact report code are the starting point for an issuer lookup.

  2. Client

    The client is Valor Peptides. The report describes the sample Valor submitted under this name.

  1. Report code and dates

    Report 3ZGM-4DQL; sample received 2026-09-21, certificate published 2026-09-24. Published is the date printed here; it is not labelled an analysis date.

  1. Identity, nominal size and lot

    The nominal sample size is 70.0 mg and the lot is ARC-GL70-009. Match the compound, size and lot when comparing a product with this report.

  1. Measured quantity and purity

    The headline measured quantity is 61.79 mg, and the reported chromatographic purity is 99.84%. Quantity and purity answer different questions.

  1. Laboratory results

    Identity and purity are marked Conforms. Quantity is marked Measured: that label records an amount rather than a laboratory pass/fail judgment against the nominal size.

  1. Chromatogram

    The plotted HPLC signal accompanies the reported purity result. Peak area, chromatographic purity and vial mass are different measurements.

  1. Certification and lookup

    The footer repeats 3ZGM-4DQL beside the issuer QR code and certification date. Use the specific issuer record linked below to compare the complete PDF.

What this report shows

Identity and reported purity

The overall chromatographic purity is 99.84%, while the component purities range from 99.592% to 99.919%. These percentages describe the analyzed material; they are not the percentage of the nominal 70 mg present in the vial.

Measured amount

The three measured components total 61.789 mg, which rounds to the reported 61.79 mg. That is 88.27% of the 70 mg nominal size, or 8.21 mg lower. The report labels quantity Measured, so we retain both figures instead of turning the nominal size into a laboratory pass/fail claim.

Test coverage

All seven analytical categories are represented: identity, purity, quantity, endotoxin, rapid PCR screening, elemental impurities and fentanyl screening. They belong to one sample report set across three pages, not seven independent batches.

Report date and batch

This report is published September 24, 2026 for lot ARC-GL70-009. A product or vial needs matching compound, nominal size and lot to be linked to this specific sample. A later PDF upload path does not change the printed publication date.

All reported results
Transcribed results from Accumark report 3ZGM-4DQL
ResultReported valueSpecification or contextLab status
IdentityGHK-Cu, BPC-157, TB500 (17–23 Fragment)Same three named componentsConforms
Total quantity61.79 mg70.0 mg nominal size; quantity reported as measuredMeasured
Overall chromatographic purity99.84%>98.0%Conforms
GHK-Cu40.794 mg; 99.919% purityQuantity measured; purity >98.0%Measured / Conforms
BPC-15710.185 mg; 99.592% purityQuantity measured; purity >98.0%Measured / Conforms
TB500 (17–23 Fragment)10.81 mg; 99.778% purityQuantity measured; purity >98.0%Measured / Conforms
Endotoxin USP85 LAL< LOQ; LOQ 2.5 EU/mL≤5 EU/mLConforms
Rapid PCR screeningNot DetectedNot DetectedConforms
Fentanyl strip screeningNot DetectedQualitative; 200 ng/mL detection threshold in prepared solutionConforms
Elemental impurities, with the laboratory's printed limits and quantification thresholds
ElementResultLimitLOQLab status
Lead< LOQ≤ 200 µg/g3.2 µg/gConforms
Arsenic< LOQ≤ 600 µg/g55 µg/gConforms
Cadmium< LOQ≤ 80 µg/g40 µg/gConforms
Mercury< LOQ≤ 120 µg/g40 µg/gConforms

LOQ means limit of quantification. These metal limits use the issuer's stated 25 mg/day calculation basis. The fentanyl strip uses a 200 ng/mL detection threshold in prepared solution.

Source and verification

The retained vendor PDF is byte-for-byte identical to the downloaded official issuer PDF. We read all 3 pages, including the additional test results.

All Valor GLOW COAs

Current and historical reports at every retained strength. The marked-up report above is one example.

14 reports · 13 COA verified · 1 not verified

Valor Peptides

7-test panelPurity · Identity · Content · Endotoxin · Heavy metals · Sterility · Fentanyl screen

Lot ARC-GL70-009

Valor Peptides

6-test panelPurity · Identity · Content · Endotoxin · Sterility · Fentanyl screen

Lot ARC-GL70-009

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-008

Valor Peptides

3-test panelPurity · Identity · Content

Lot ARC-GL70-008

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-007

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-006

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-004

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-004

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL90-001

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-005

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-009

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-003

Valor Peptides

5-test panelPurity · Identity · Content · Endotoxin · Sterility

Lot ARC-GL70-002

Valor Peptides

4-test panelPurity · Identity · Content · Endotoxin

Lot GW0002