Valor Peptides GLOW COA analysis
99.84% chromatographic purity; 61.79 mg measured against the 70 mg label.
- Report
- 3ZGM-4DQL
- Published
- Lot
- ARC-GL70-009
- Complete document
- 3 pages
The report, marked up
Laboratory
Accumark Labs issued this certificate. Its name and the exact report code are the starting point for an issuer lookup.
Client
The client is Valor Peptides. The report describes the sample Valor submitted under this name.
Report code and dates
Report 3ZGM-4DQL; sample received 2026-09-21, certificate published 2026-09-24. Published is the date printed here; it is not labelled an analysis date.
Identity, nominal size and lot
The nominal sample size is 70.0 mg and the lot is ARC-GL70-009. Match the compound, size and lot when comparing a product with this report.
Measured quantity and purity
The headline measured quantity is 61.79 mg, and the reported chromatographic purity is 99.84%. Quantity and purity answer different questions.
Laboratory results
Identity and purity are marked Conforms. Quantity is marked Measured: that label records an amount rather than a laboratory pass/fail judgment against the nominal size.
Chromatogram
The plotted HPLC signal accompanies the reported purity result. Peak area, chromatographic purity and vial mass are different measurements.
Certification and lookup
The footer repeats 3ZGM-4DQL beside the issuer QR code and certification date. Use the specific issuer record linked below to compare the complete PDF.
Page 1 of 3. Tap a section to open the complete page.
Laboratory
Accumark Labs issued this certificate. Its name and the exact report code are the starting point for an issuer lookup.
Client
The client is Valor Peptides. The report describes the sample Valor submitted under this name.
Report code and dates
Report 3ZGM-4DQL; sample received 2026-09-21, certificate published 2026-09-24. Published is the date printed here; it is not labelled an analysis date.
Identity, nominal size and lot
The nominal sample size is 70.0 mg and the lot is ARC-GL70-009. Match the compound, size and lot when comparing a product with this report.
Measured quantity and purity
The headline measured quantity is 61.79 mg, and the reported chromatographic purity is 99.84%. Quantity and purity answer different questions.
Laboratory results
Identity and purity are marked Conforms. Quantity is marked Measured: that label records an amount rather than a laboratory pass/fail judgment against the nominal size.
Chromatogram
The plotted HPLC signal accompanies the reported purity result. Peak area, chromatographic purity and vial mass are different measurements.
Certification and lookup
The footer repeats 3ZGM-4DQL beside the issuer QR code and certification date. Use the specific issuer record linked below to compare the complete PDF.
What this report shows
Identity and reported purity
The overall chromatographic purity is 99.84%, while the component purities range from 99.592% to 99.919%. These percentages describe the analyzed material; they are not the percentage of the nominal 70 mg present in the vial.
Measured amount
The three measured components total 61.789 mg, which rounds to the reported 61.79 mg. That is 88.27% of the 70 mg nominal size, or 8.21 mg lower. The report labels quantity Measured, so we retain both figures instead of turning the nominal size into a laboratory pass/fail claim.
Test coverage
All seven analytical categories are represented: identity, purity, quantity, endotoxin, rapid PCR screening, elemental impurities and fentanyl screening. They belong to one sample report set across three pages, not seven independent batches.
Report date and batch
This report is published September 24, 2026 for lot ARC-GL70-009. A product or vial needs matching compound, nominal size and lot to be linked to this specific sample. A later PDF upload path does not change the printed publication date.
All reported results
| Result | Reported value | Specification or context | Lab status |
|---|---|---|---|
| Identity | GHK-Cu, BPC-157, TB500 (17–23 Fragment) | Same three named components | Conforms |
| Total quantity | 61.79 mg | 70.0 mg nominal size; quantity reported as measured | Measured |
| Overall chromatographic purity | 99.84% | >98.0% | Conforms |
| GHK-Cu | 40.794 mg; 99.919% purity | Quantity measured; purity >98.0% | Measured / Conforms |
| BPC-157 | 10.185 mg; 99.592% purity | Quantity measured; purity >98.0% | Measured / Conforms |
| TB500 (17–23 Fragment) | 10.81 mg; 99.778% purity | Quantity measured; purity >98.0% | Measured / Conforms |
| Endotoxin USP85 LAL | < LOQ; LOQ 2.5 EU/mL | ≤5 EU/mL | Conforms |
| Rapid PCR screening | Not Detected | Not Detected | Conforms |
| Fentanyl strip screening | Not Detected | Qualitative; 200 ng/mL detection threshold in prepared solution | Conforms |
| Element | Result | Limit | LOQ | Lab status |
|---|---|---|---|---|
| Lead | < LOQ | ≤ 200 µg/g | 3.2 µg/g | Conforms |
| Arsenic | < LOQ | ≤ 600 µg/g | 55 µg/g | Conforms |
| Cadmium | < LOQ | ≤ 80 µg/g | 40 µg/g | Conforms |
| Mercury | < LOQ | ≤ 120 µg/g | 40 µg/g | Conforms |
LOQ means limit of quantification. These metal limits use the issuer's stated 25 mg/day calculation basis. The fentanyl strip uses a 200 ng/mL detection threshold in prepared solution.
Source and verification
The retained vendor PDF is byte-for-byte identical to the downloaded official issuer PDF. We read all 3 pages, including the additional test results.
All Valor GLOW COAs
Current and historical reports at every retained strength. The marked-up report above is one example.
14 reports · 13 COA verified · 1 not verified
Valor Peptides
7-test panelPurity · Identity · Content · Endotoxin · Heavy metals · Sterility · Fentanyl screen
Lot ARC-GL70-009
Valor Peptides
6-test panelPurity · Identity · Content · Endotoxin · Sterility · Fentanyl screen
Lot ARC-GL70-009
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-008
Valor Peptides
3-test panelPurity · Identity · Content
Lot ARC-GL70-008
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-007
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-006
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-004
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-004
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL90-001
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-005
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-009
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-003
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-GL70-002
Valor Peptides
4-test panelPurity · Identity · Content · Endotoxin
Lot GW0002