Valor Peptides BPC-157 COA analysis
99.871% chromatographic purity; 11.192 mg measured against the 10 mg label.
- Report
- W9PN-28GT
- Published
- Lot
- ARC-BP10-007
- Complete document
- 2 pages
The report, marked up
Laboratory
Accumark Labs issued this certificate. Its name and the exact report code are the starting point for an issuer lookup.
Client
The client is Valor Peptides. The report describes the sample Valor submitted under this name.
Report code and dates
Report W9PN-28GT; sample received 2026-08-25, certificate published 2026-09-02. Published is the date printed here; it is not labelled an analysis date.
Identity, nominal size and lot
The nominal sample size is 10.0 mg and the lot is ARC-BP10-007. Match the compound, size and lot when comparing a product with this report.
Measured quantity and purity
The headline measured quantity is 11.192 mg, and the reported chromatographic purity is 99.871%. Quantity and purity answer different questions.
Laboratory results
Identity and purity are marked Conforms. Quantity is marked Measured: that label records an amount rather than a laboratory pass/fail judgment against the nominal size.
Chromatogram
The plotted HPLC signal accompanies the reported purity result. Peak area, chromatographic purity and vial mass are different measurements.
Certification and lookup
The footer repeats W9PN-28GT beside the issuer QR code and certification date. Use the specific issuer record linked below to compare the complete PDF.
Page 1 of 2. Tap a section to open the complete page.
Laboratory
Accumark Labs issued this certificate. Its name and the exact report code are the starting point for an issuer lookup.
Client
The client is Valor Peptides. The report describes the sample Valor submitted under this name.
Report code and dates
Report W9PN-28GT; sample received 2026-08-25, certificate published 2026-09-02. Published is the date printed here; it is not labelled an analysis date.
Identity, nominal size and lot
The nominal sample size is 10.0 mg and the lot is ARC-BP10-007. Match the compound, size and lot when comparing a product with this report.
Measured quantity and purity
The headline measured quantity is 11.192 mg, and the reported chromatographic purity is 99.871%. Quantity and purity answer different questions.
Laboratory results
Identity and purity are marked Conforms. Quantity is marked Measured: that label records an amount rather than a laboratory pass/fail judgment against the nominal size.
Chromatogram
The plotted HPLC signal accompanies the reported purity result. Peak area, chromatographic purity and vial mass are different measurements.
Certification and lookup
The footer repeats W9PN-28GT beside the issuer QR code and certification date. Use the specific issuer record linked below to compare the complete PDF.
What this report shows
Identity and reported purity
The reported chromatographic purity is 99.871%, above the report’s >98.0% specification. Although the template’s headline says Total Blend Purity, the declared identity and results table name the single compound BPC-157.
Measured amount
The measured amount is 11.192 mg: 111.92% of the nominal 10 mg, or 1.192 mg above it. Accumark labels quantity Measured. The report’s Conforms judgments apply to identity, purity and the two screening rows.
Test coverage
The report documents five analytical categories: identity, purity, quantity, endotoxin and rapid PCR screening. The LAL and PCR rows are qualitative Pass results; no precise endotoxin number is printed. Heavy metals and fentanyl are not reported in this set.
Report date and batch
Accumark received the sample August 25, 2026 and published report W9PN-28GT on September 2 for lot ARC-BP10-007. This is one report set with two pages. A matching product lot is required to associate current stock with the sample.
All reported results
| Result | Reported value | Specification or context | Lab status |
|---|---|---|---|
| Identity | BPC-157 | BPC-157 | Conforms |
| Quantity | 11.192 mg | 10.0 mg nominal size; quantity reported as measured | Measured |
| Chromatographic purity | 99.871% | >98.0% | Conforms |
| Endotoxin LAL | Pass | ≤5.0 EU/mL | Conforms |
| Rapid PCR screening | Pass | Not Detected | Conforms |
Source and verification
The retained vendor PDF is byte-for-byte identical to the downloaded official issuer PDF. We read all 2 pages, including the additional test results.
All Valor BPC-157 COAs
Current and historical reports at every retained strength. The marked-up report above is one example.
15 reports · 15 COA verified · 0 not verified
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP10-007
Valor Peptides
4-test panelPurity · Identity · Content · Endotoxin
Lot ARC-BP10-007
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP20-004
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP20-005
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP10-005
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP20-003
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP20-002
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP20-001
Valor Peptides
4-test panelPurity · Identity · Content · Endotoxin
Lot ARC-BP10-004
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP10-003
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot ARC-BP10-002
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot BP2002
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot BP1006
Valor Peptides
4-test panelPurity · Identity · Content · Endotoxin
Lot ARC-BP10-001
Valor Peptides
5-test panelPurity · Identity · Content · Endotoxin · Sterility
Lot BP1002